THT2 - Temperature and hygrometer for Modbus RTU over RS485

Temperature and hygrometer to measure temperature, humidity and calculate dew point.

The meter is used with a sensor and there are two types of sensors. Either the temperature sensor that only measures temperature. Or the temperature and humidity sensor that measures temperature and humidity and calculates dew point. Each sensor is ordered separately and is available in different lengths. The sensors are connected to the meter with a bayonet coupling.

Communication to the meter takes place with Modbus RTU via RS485. Configuration and testing of the meter is done with the software Modbus Configurator. Testing of the meter can also be done with the PiiGAB M-Bus Wizard software.

The meter can be combined with USB to RS485 cable CAB-115 which combines voltage supply with data communication. In addition, the meter can be connected to an M-Bus network with the Modbus2MBus application in the PiiGAB M-Bus 900S.

Specification for THT2

Compatible sensors: temperature and humidity or temperature only (sensors sold separately).
Calculates temperatures in different units (°C, °F or K). Celsius by default.
Modbus RTU over RS485.
RS485 communication: 9600 baud, 8 data bits, no parity and 1 stop bit.
Voltage supply: 5-30VDC. 8mA at 12VDC.
The power supply is sold separately.
DIN mounting is sold separately.

Article number

PA-THT2.

Downloadable files

Temperature sensor

Measuring range: -55°C to + 125°C
Available lengths: 1m, 3m, 5m, 10m, 15m or 20m.
IP: 68.
Cable diameter: 4.3mm.
Cable temperature resistance: -60°C to + 200°C.

Article number

PA-TEMP_x.
x indicates the length of the sensor.

Temperature and humidity sensors

Measure temperature range: -40°C to + 123.8°C with 0.1°C resolution.
Measure humidity range: 0 to 100%.
Calculates dew point.
Available lengths: 1m, 3m, 5m, 10m, 15m or 20m.
IP: 54.
Cable diameter: 4.7mm.
Cable temperature resistance: -60°C to + 200°C.

Article number

PA-THE_x.
x indicates the length of the sensor.

Mounting for DIN rail

For 35mm DIN rail.
NS35.

Article number

PA-DIN_01

Power supply

The meter has terminal blocks for connecting the voltage supply. Use TU-PSLR24 as DIN-mounted transformer or standard voltage adapter PA-PWR_12 with wall connection.

Beställ din Digitala/Analoga M-Bus omvandlare från Relay här!

Copyright © 2025 by PiiGAB Processinformation i Göteborg AB
All trademarks or registered trademarks on the website are the property of their respective owners
en_GB