{"id":59164,"date":"2020-10-26T14:17:31","date_gmt":"2020-10-26T12:17:31","guid":{"rendered":"https:\/\/www.piigab.com\/?post_type=ufaq&#038;p=59164"},"modified":"2022-10-04T08:21:20","modified_gmt":"2022-10-04T06:21:20","slug":"lasa-m-bus-matare-fran-extern-m-bus-omvandlare","status":"publish","type":"ufaq","link":"https:\/\/www.piigab.com\/en\/faq\/lasa-m-bus-matare-fran-extern-m-bus-omvandlare\/","title":{"rendered":"Read M-Bus meters from external M-Bus master"},"content":{"rendered":"<div  class=\"ewd-ufaq-faq-list ewd-ufaq-page-type-distinct\" id='ewd-ufaq-faq-list'>\n\n\t<input type='hidden' name='show_on_load' value='' id='ewd-ufaq-show-on-load' \/>\n<input type='hidden' name='include_category' value='' id='ewd-ufaq-include-category' \/>\n<input type='hidden' name='exclude_category' value='' id='ewd-ufaq-exclude-category' \/>\n<input type='hidden' name='orderby' value='title' id='ewd-ufaq-orderby' \/>\n<input type='hidden' name='order' value='asc' id='ewd-ufaq-order' \/>\n<input type='hidden' name='post_count' value='-1' id='ewd-ufaq-post-count' \/>\n<input type='hidden' name='current_url' value='\/en\/wp-json\/wp\/v2\/ufaq\/59164' id='ewd-ufaq-current-url' \/>\n\t\n\t\n\t<div class='ewd-ufaq-faqs'>\n\n\t\t<div  class=\"ewd-ufaq-faq-div ewd-ufaq-faq-column-count-two ewd-ufaq-faq-responsive-columns-1 ewd-ufaq-faq-display-style-minimalist ewd-ufaq-can-be-toggled\" id='ewd-ufaq-post-59164-rgx2WztvG9' data-post_id='59164'>\n\n\t<div class='ewd-ufaq-faq-title ewd-ufaq-faq-toggle'>\n\t\n\t<a class='ewd-ufaq-post-margin'  href='#' role=\"button\">\n\n\t\t<div class='ewd-ufaq-post-margin-symbol ewd-ufaq-square'>\n\t\t\t<span >A<\/span>\n\t\t<\/div>\n\n\t\t<div class='ewd-ufaq-faq-title-text'>\n\n\t\t\t<h4>\n\t\t\t\tRead M-Bus meters from external M-Bus master\t\t\t<\/h4>\n\n\t\t<\/div>\n\n\t\t<div class='ewd-ufaq-clear'><\/div>\n\n\t<\/a>\n\t\n<\/div>\n\t\n\t<div class='ewd-ufaq-faq-body' >\n\n\t\t\n\t\t\t\n\t\t\n\t\t\t<div class='ewd-ufaq-post-margin ewd-ufaq-faq-post'>\n\t\n<p>Read M-Bus meters from external M-Bus master<\/p>\n\n\n\n<p>The following list instructs how to configure a PiiGAB M-Bus 900\/900S as an M-Bus slave, i.e. one or two external M-Bus masters can read the M-Bus meter connected to the gateway.<\/p>\n\n\n\n<p><em>Notice: On PiiGAB M-Bus 900 there can only be one external M-Bus master connected.<\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Start the gateway\u2019s web interface in any web browser.<\/li><li>Go to the <em>Configuration<\/em> page.<\/li><li>Select any slave port to configure as an M-Bus slave.<\/li><li>Specify the following parameters:<ul><li>Type: Serial.<\/li><li>Com port: <em>M-Bus Slave 1<\/em> or <em>M-Bus Slave 2<\/em>.<\/li><li>Baud rate: The specified communication speed on the M-Bus loop.<\/li><li>Bit Number: Number of data bits on the M-Bus loop. Standard 8 bits.<\/li><li>Parity: The parity for the M-Bus loop. Standard Even parity.<\/li><li>Stop Bit: Number of stop bits on the M-Bus loop. Standard 1 stop bits.<\/li><li>Timeout: Expected time to get answer from the M-Bus meter.<\/li><li>Protocol: The data protocol on the M-Bus loop. Standard M-Bus.<\/li><\/ul><\/li><li>Press the <em>Save settings<\/em>.<\/li><li>Connect the external M-Bus loop from the external M-Bus master to the following pins:<ul><li>PiiGAB M-Bus 900: Pins 15-18. Notice only one M-Bus slave.<\/li><li>PiiGAB M-Bus 900S: Pins 15-16 (M-Bus slave 1) or pins 17-18 (M-Bus slave 2).<\/li><\/ul><\/li><\/ol>\n\n\n\n<p>The picture shows Slave port 2 is configured for M-Bus slave 1 on 2400 baud, 8 data bits, even parity, 1 stop bit, 2000ms as timeout and M-Bus communication. <em>M-Bus Slave 1<\/em> at 2400 baud, 8 data bits, even parity, 1 stop bit, 2000ms timeout and M-Bus communication.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.piigab.com\/wp-content\/uploads\/2017\/07\/M-BusSlave1.png\"><img decoding=\"async\" loading=\"lazy\" width=\"300\" height=\"118\" src=\"https:\/\/www.piigab.com\/wp-content\/uploads\/M-BusSlave1-300x118-1.png\" alt=\"\" class=\"wp-image-59165\" srcset=\"https:\/\/www.piigab.com\/wp-content\/uploads\/M-BusSlave1-300x118-1.png 300w, https:\/\/www.piigab.com\/wp-content\/uploads\/M-BusSlave1-300x118-1-16x6.png 16w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/figure>\n\n\n\n<p>Note:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Make sure the gateway doesn\u2019t use the specific M-Bus slave port anywhere else. For instance any other slave ports or the Modbus2MBus and\/or the Wireless applications.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.piigab.com\/wp-content\/uploads\/2017\/07\/MBusSlavePortsPins.png\"><img decoding=\"async\" loading=\"lazy\" width=\"300\" height=\"172\" src=\"https:\/\/www.piigab.com\/wp-content\/uploads\/MBusSlavePortsPins-300x172-1.png\" alt=\"\" class=\"wp-image-59166\" srcset=\"https:\/\/www.piigab.com\/wp-content\/uploads\/MBusSlavePortsPins-300x172-1.png 300w, https:\/\/www.piigab.com\/wp-content\/uploads\/MBusSlavePortsPins-300x172-1-16x9.png 16w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/figure>\n<\/div>\n\t\t\n\t\t\t<div class='ewd-ufaq-faq-custom-fields'>\n\n\t\n<\/div>\n\t\t\n\t\t\t<div class='ewd-ufaq-faq-categories'>\n\t\n\tCategory\n\t\n\t\tPiiGAB 900S\/T\n\t\n<\/div>\n\t\t\n\t\t\t\n\t\t\n\t\t\t<div class='ewd-ufaq-ratings'>\n\t\n\t<div class='ewd-ufaq-ratings-label'>\n\t\tDo you think the answer helped you?\t<\/div>\n\t\n\t<div class='ewd-ufaq-rating-button ewd-ufaq-up-vote ewd-ufaq-ratings-default-image' data-faq_id='59164'>\n\t\t<img decoding=\"async\" src=\"https:\/\/www.piigab.com\/wp-content\/plugins\/ultimate-faqs\/assets\/img\/Thumbs-up-icon.png\" alt=\"Thumbs Up Icon\">\t\t<span>0<\/span>\n\t<\/div>\n\t\n\t<div class='ewd-ufaq-rating-button ewd-ufaq-down-vote ewd-ufaq-ratings-default-image' data-faq_id='59164'>\n\t\t<img decoding=\"async\" src=\"https:\/\/www.piigab.com\/wp-content\/plugins\/ultimate-faqs\/assets\/img\/Thumbs-down-icon.png\" alt=\"Thumbs Down Icon\">\t\t<span>0<\/span>\n\t<\/div>\n<\/div>\n\n<div class='ewd-ufaq-clear'><\/div>\n\t\t\n\t\t\t\n\t\t\n\t\t\t<div class='ewd-ufaq-permalink'>\n\t\n\t<a href='https:\/\/www.piigab.com\/en\/faq\/lasa-m-bus-matare-fran-extern-m-bus-omvandlare\/'>\n\t\t\n\t\tLink to this article\t\t\t\n\t<\/a>\n\n<\/div>\n\t\t\n\t\t\t\n\t\t\n\t\t\t\n\t\t\n\t<\/div>\n\n<\/div>\n\t<\/div>\n\n\t\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A L\u00e4sa M-Bus m\u00e4tare fr\u00e5n extern M-Bus omvandlare L\u00e4sa M-Bus m\u00e4tare fr\u00e5n extern M-Bus omvandlare F\u00f6ljande visar hur man konfigurerar en PiiGAB M-Bus 900\/900S som M-Bus slav, dvs att en eller tv\u00e5 externa M-Bus omvandlare kan l\u00e4sa M-Bus m\u00e4tarna kopplade till omvandlaren. Obs: F\u00f6r PiiGAB M-Bus 900 kan bara en extern M-Bus master inkopplas. Start [&hellip;]<\/p>","protected":false},"author":5,"comment_status":"open","ping_status":"closed","template":"","ufaq-category":[285],"ufaq-tag":[],"class_list":["post-59164","ufaq","type-ufaq","status-publish","hentry","ufaq-category-900s-t"],"_links":{"self":[{"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/ufaq\/59164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/ufaq"}],"about":[{"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/types\/ufaq"}],"author":[{"embeddable":true,"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/comments?post=59164"}],"wp:attachment":[{"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/media?parent=59164"}],"wp:term":[{"taxonomy":"ufaq-category","embeddable":true,"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/ufaq-category?post=59164"},{"taxonomy":"ufaq-tag","embeddable":true,"href":"https:\/\/www.piigab.com\/en\/wp-json\/wp\/v2\/ufaq-tag?post=59164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}